Signal-integrity-critical assemblies for network infrastructure, data centres, and communication equipment: impedance controlled, properly shielded, and verified at build to the performance levels the equipment demands.

50Ω
/ 75Ω controlled
EMI
Shielded builds
ISO
9001:2015
Telecommunications wire harness
Telecommunications: Network & Data Centre Cabling

“Signal integrity in a telecom assembly isn't just about the cable spec. It's about the connector termination quality, shielding continuity, and the consistency of every build in the batch.”

Engineering Challenges

What telecom assemblies
cannot compromise on.

01

Signal Integrity & Impedance Control

High-frequency signal transmission is extremely sensitive to impedance discontinuities, connector quality, and cable geometry. A poorly terminated coaxial connector or mismatched impedance on a twisted-pair run causes reflections, signal degradation, and bit-error rate increases that are difficult to diagnose post-installation.

02

Shielding Effectiveness

Data centre and network environments are electrically noisy. Power cables, switching power supplies, and fluorescent lighting all radiate EMI. Cable assemblies carrying sensitive signals require effective shielding, and that shielding must be correctly terminated to provide a continuous ground reference.

03

High-Density Connector Systems

Rack-mount equipment uses high-density connector assemblies that must mate reliably and repeatedly under the access constraints of populated rack environments. Connector pin retention, keying, and insertion force must all be within spec; a connector that fails to seat in a live rack is a service outage.

04

Long Service Life & Reliability

Telecom infrastructure is expected to operate continuously for years without field maintenance. Assemblies that cannot sustain the environmental conditions of their installation, including temperature, humidity, and vibration, represent a reliability risk to the entire system.

Technical Specification

Built to maintain signal integrity.

Standard coaxial and structured cabling builds available. Custom configurations and non-standard connector combinations reviewed before production is confirmed.

Request a Quote
Coaxial: RG6, RG58, RG174, LMR-195, LMR-400 and equivalents
Connectors: SMA, BNC, N-type, TNC, MCX, MMCX, F-type
Impedance: 50Ω and 75Ω controlled assemblies
Twisted pair: Cat5e, Cat6, Cat6A (terminated and tested)
Fibre-optic pigtails and patch assemblies available
Shielding: foil, braid, or combination (continuity verified)
High-density rack cable assemblies to specification
VSWR and insertion loss testing available on request
Standards Applied
TIA-568 · IEC 61156 · IPC-A-620 Class 3
ISO 9001:2015 certified process on every production run